Skip Navigation


Europace Advance Access originally published online on July 10, 2008
Europace 2008 10(10):1228-1229; doi:10.1093/europace/eun184
This Article
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow All Versions of this Article:
10/10/1228    most recent
eun184v1
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Add to My Personal Archive
Right arrow Download to citation manager
Right arrowRequest Permissions
Google Scholar
Right arrow Articles by Yamada, T.
Right arrow Articles by Kay, G. N.
PubMed
Right arrow PubMed Citation
Right arrow Articles by Yamada, T.
Right arrow Articles by Kay, G. N.
Social Bookmarking
 Add to CiteULike   Add to Connotea   Add to Del.icio.us  
What's this?

Published on behalf of the European Society of Cardiology. All rights reserved. © The Author 2008. For permissions please email: journals.permissions@oxfordjournals.org


CASE REPORTS

Successful catheter ablation of premature ventricular contractions originating from the tricuspid annulus using a Halo-type catheter

Takumi Yamada*, Jeffery Scott Allison, Hugh Thomas McElderry, Harish Doppalapudi, Andrew E. Epstein, Vance J. Plumb and George Neal Kay

Division of Cardiovascular Disease, University of Alabama at Birmingham, VH B147, 1670 University Boulevard, 1530 3rd Avenue South, Birmingham, AL 35294-0019, USA

A 31-year-old woman with idiopathic premature ventricular contractions originating from the tricuspid annulus (TA) underwent electrophysiological testing. Activation mapping with a 20-pole bipolar Halo-type catheter positioned along the TA revealed the earliest ventricular activation at a site between 7 and 8 o'clock along the TA. A reversal in the polarity of the local ventricular electrograms was observed between the two neighbouring electrode pairs of the TA catheter. Successful catheter ablation was achieved at the ventricular site between those electrode pairs. A Halo-type catheter may be effective for mapping and catheter ablation of ventricular arrhythmias originating from the TA.


* Corresponding author. Tel: +1 205 975 4724; fax: +1 205 975 4720. E-mail address: takumi-y{at}fb4.so-net.ne.jp

Manuscript submitted 5 April 2008. Accepted after revision 23 June 2008.


Add to CiteULike CiteULike   Add to Connotea Connotea   Add to Del.icio.us Del.icio.us    What's this?




Disclaimer:
Please note that abstracts for content published before 1996 were created through digital scanning and may therefore not exactly replicate the text of the original print issues. All efforts have been made to ensure accuracy, but the Publisher will not be held responsible for any remaining inaccuracies. If you require any further clarification, please contact our Customer Services Department.